Model pH 200 pH/mV/Temp Meter
Advantages
- pH / redox measurement and temperature measurement (Pt1000 or NTC 30kOhm)
- Automatic temperature compensation (ATC)
- Auto Hold function
- Internal memory for 20 data sets
- Automatic buffer recognition with Tintometer standard or DIN or individual buffer
- 1, 2 and 3 point calibration
- Low battery and battery change indicator
- Sensor evaluation in the display based on the calibration result (from 10 to 100%)
- Battery operation period up to 15000 hours
- Shock-absorbing rubber protective armouring
- Waterproof
The Series 200 Electrochemistry instruments are rugged, high performance handheld meters that are specifically designed for use in both the laboratory and the field.
The meters come standard with the following features:
- Waterproof housing with built-in storage compartment for probes.
- A built-in support arm can be flipped up to suspend the meter on nearby objects, such as pipes or branches.
- A simple user interface for easy meter operation both outdoors and in the laboratory.
- The automatic Hold function which “freezes” stable measuring data in the display and indicates the presence of reliable and reproducible results.
- The internal memory allows storage of 20 data sets to facilitate subsequent evaluation.
- The integral automatic switch-off feature, varying from 1 to 120 minutes, to preserve the battery life of the units.
The power consumption of all three units has been optimized. As a result, the 4 x 1.5 V integrated batteries have an operating life of up to 15,000 hours, depending on the version.
Specifications
| pH: | 0.00 to 14.00 |
| Accuracy: | ± 0.01 pH (at nominal temperature, unit ± 1 digit) |
| Temperature: | -10.0 to +110.0 °C 14.0 to 230.0 °F |
| Accuracy: | ±0.2 °C and ± 0.4 °C |
| mV: | -1999 to +2000 mV |
| Relative mV: | -1792 to +2206 Rel mV |
| Accuracy: | ± 0.1 % FS (mV or Rel mV) |
| Sensor connections: | DIN 19262 and two 4 mm banana sockets “Temp” and “Ref” |
| Input resistance: | >1012 Ohm (typ.) |
| Input current: | <1 pA |
| Nominal temperature: | -4 – 158 °F |
| Operating temperature: 0 to +50 °C | 32 – 122 °F |
| Power supply: | 4 x 1.5V battery, type AA supply Operating time up to >15,000h |
| Power consumption: | 0.2 mA |
| Auto-Off function: | 0 – 120 minutes |
| Calibration: | 1, 2 or 3 point calibration with auto buffer recognition Orbeco-Hellige buffer, DIN buffer or user-selectable buffer |
| Certification: | CE |
Ordering Information
| Part Number | Description |
| L721200 | Model pH 200 without electrode, with batteries, instruction manual, and carrying case |
| L721220 | Model pH 200 (SET 1) includes instrument, batteries, pH/temp. plastic-electrode type 230, pH Buffer Set, in a case, with manual. |
| L721221 | Model pH 200 (SET 2) as SET1, but with pH/temp. plastic electrode type 225, and temperature sensor Pt 1000 |
| L721225 | pH-electrode plastic/gel-type 225 |
| L721230 | pH/temp.-electrode type 230, plastic/gel/temperature NTC30kOhm |
| L721235 | pH-electrode glass/gel-type 235 |
| L721240 | Redox-electrode plastic-type 240 |
| L721245 | Temperature sensor, PT1000 |
| L721250 | pH Buffer Set 4.00/7.00/10.00 (75°F) 1 liter |
| L721252 | pH Buffer 4.00 (75°F) 1 liter |
| L721254 | pH Buffer 7.00 (75°F) 1 liter |
| L721256 | pH Buffer 10.00 (75°F) 1 liter |
| L418609 | KCl-solution, 3 molar saturated with AgCl, 100 ml |
| L721260 | Adapter cable DIN19262 – BNC |
| L721265 | Adapter cable DIN 19262 S7 plug-head |
| L725020 | Case, Series 200 with foam insert |