Series 150: Multi-Parameter E-Chem Meter
The Series 150 Multiparameter Electro-Chemistry meter combines the testing abilities of several different instruments. The instrument has the ability to measure pH/ORP, Dissolved Oxygen, and Conductivity/TDS and has several convenient features such as the ability to store data with time and date stamp, then easily transfer the data to a computer by the RS232/USB connections.
| General Specifications: | ||
| Data Output: | RS232 PC Serial Interface | |
| Power Supply: | DC: 1.5V or 9V adapter Battery: 4 x AA | |
| Instrument Dimensions: | 220 x 120 x 40 mm | |
| Instrument Weight: | 6 oz (including batteries) | |
| pH Specifications | ||
| Range: | 0 – 14 pH -1999 – 1999 mV | |
| Resolution: | 0 – 14 pH: 0.01 pH 0 – 1999 mV: 1 mV | |
| Accuracy: | 0 – 14 pH: ± 0.02 pH + 2 Digits 0 – 1999 mV: ±0.5% + 2 digits | |
| Temperature Compensation: | Manual: 0 – 100°C Automatic (ATC) | |
| Calibration: | 3 point calibration (pH 4, 7 & 10 pH) | |
| Dissolved Oxygen Specifications | ||
| Range: | Dissolved O2: 0 – 20 mg.L Oxygen in Air: 0 – 100.0% Temperature: 0 – 50°C | |
| Resolution: | Dissolved O2: 0.1 mg/l Temperature: 0.1°C | |
| Accuracy (23 ± 5°C): | Dissolved O2: ± 0.4 mg.L Oxygen in Air: ± 0.7% O2 Temperature: ± 0.8°C | |
| Salinity Correction: | 0 – 39% salt | |
| Air Pressure Compensation: | 0 – 8900 Meter | |
| Conductivity / TDS Specifications | ||
| Range / Resolution: | Conductivity: 0 – 200 μS: 0.1 μS 0.2 – 2.000 mS: 0.001 mS 2 – 20.00 mS: 0.01 mS TDS: 0 – 132 ppm: 0.1 ppm 132 – 1,320 ppm: 1 ppm 1,320 – 13,200 ppm: 10 ppm 13,200 – 132,000: 100 ppm Temperature: 0 – 60°C: 0.1°C | |
| Accuracy: | ± 2% Full Scale ±0.8 °C | |
| Function: | Conductivity: μS, mS TDS: PPM Temperature: °C or °F | |
| Description | Includes | Part Number |
| Series 150 Multi-Parameter E-Chem Meter | Instrument with batteries, pH electrode, Temperature probe, Conductivity probe, Oxygen sensor, pH 4.00 & 7.00 Solutions, Electrolyte Solution, 2 membrane heads, instruction Manual and carrying case. | L724200 |
| Description | Qty. | Part Number |
| pH Electrode: Plastic/Gel type, BNC-plug, 1M | EA | L721330 |
| Redox Electrode: Plastic/Gel type, BNC-plug, 1M | EA | L721242 |
| Conductivity Probe: 1.2 Meter Cable | EA | L724400 |
| Oxygen Sensor: 4 Meter Cable | EA | L722410 |
| Spare Membrane: for Oxygen Sensor | EA | L724460 |
| Electrolyte Solution: for Oxygen Sensor | L724470 | |
| Temperature Probe: PT1000, 1.5 Meter Cable | EA | L724420 |
| pH Buffer Solution, 4.00 | 500 ml | R-5012-4 |
| pH Buffer Solution, 7.00 | 500 ml | R-5013-4 |
| pH Buffer Solution, 10.0 | 500 ml | R-5014-4 |
| pH 4 Buffer Tablets | 100 ct. | RT562-0BT |
| pH 7 Buffer Tablets | 100 ct. | RT561-0BT |
| pH 10 Buffer Tablets | 100 ct. | RT562-0BT |
| RS232 Cable: for connection to a computer | EA | L724500 |
| USB Cable:for connection to a computer | EA | L724549 |
| Power Adapter (EU plug only) | EA | L724540 |
| Data Retrieve Software: Enables user to transmit stored data to a computer. | EA | L724520 |
| Data Logger / Acquisition Software: Enables user to monitor & log data to a computer. | EA | L724530 |